    Akurasi Indeks Oksigen terhadap Keberhasilan Ekstubasi pada Neonatus yang Menggunakan Ventilasi Mekanik

    The Accuracy of Oxygen Index in Relation to Successful Extubation in Neonates Undergoing Mechanical Ventilation

    Thumbnail
    View/Open
    Cover (524.8Kb)
    Fulltext (2.059Mb)
    Date
    2024
    Author
    Humairah, Siti
    Advisor(s)
    Lubis, Bugis Mardina
    Sianturi, Pertin
    Metadata
    Show full item record
    Abstract
    Backgound: Acute respiratory insufficiency often occurs in neonates requiring mechanical ventilation in the NICU as a countermeasure by intubation. Prolonged intubation can lead to complications such as ventilator-associated pneumonia, airway trauma and bronchopulmonary dysplasia (BPD). These complications often arise due to difficulties in determining the right time to extubate neonates. Further evaluation is needed on the accuracy of the oxygen index as a parameter of extubation in neonates Method: We conduct observational study with diagnostic test to evaluate the accuration of oxygen index with extubation success in neonates aged 0-28 days using mechanical ventilation on Haji Adam Malik Central General Hospital, Medan, North Sumatera, Indonesia during September 2021-2022. Result: This study was followed by 50 neonates using mechanical ventilation who were treated in the neonatal intensive care unit (NICU), 30 boys (60%) and 20 girls (40%). Seven neonates (14%) experienced failed extubation and 43 neonates (86%) were successfully extubated. The results of the oxygen index examination showed an average of 1.62 (SD = 1.41). ROC curve in predicting the success of extubation were 84% with a p value = 0.004 and 95% CI 65.1% - 100% with a cut off of 1.1. Conclusion: There was a significant relationship between the oxygen index and extubation success in neonates using mechanical ventilation
    URI
    https://repositori.usu.ac.id/handle/123456789/100440
    Collections
    • Master Theses [355]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV