• Login
    View Item 
    •   USU-IR Home
    • Faculty of Mathematics and Natural Sciences
    • Department of Physics
    • Undergraduate Theses
    • View Item
    •   USU-IR Home
    • Faculty of Mathematics and Natural Sciences
    • Department of Physics
    • Undergraduate Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Pengukuran Laju Paparan Radiasi dan Efektivitas Perisai Radiasi Pada Ruang Cs-137 di BPFK Medan

    Measurement of Radiation Exposure Rate and Effectiveness of Radiation Shielding in Cs-137 Room in BPFK Medan

    Thumbnail
    View/Open
    Cover (1.351Mb)
    Fulltext (3.239Mb)
    Date
    2024
    Author
    Fajar, Aisah
    Advisor(s)
    Barus, Diana Alemin
    Metadata
    Show full item record
    Abstract
    One of the radiation protection programs has been carried out by measuring the exposure to scattering radiation around the cesium-137 room at BPFK Medan. Measurements were made in five rooms using a babyline surveymeter. The measurements were carried out to obtain the value of radiation exposure rate in the cesium-137 room, the value of radiation exposure rate in the room around the cesium-137 room, and finally to obtain the effectiveness value of radiation shielding in BPFK. Measurements were made by observing the point to be measured, measuring and documenting. From the measurements taken, the radiation exposure rate value was obtained after passing through the shield. In the operator's room, the exposure rate is 0.00014 mSv/year; in the inventory room, 0.00007 mSv/year; in the product test lab room, 0.00016 mSv/year; in the parking lot, 0.00009 mSv/year; in the large hall meeting room, 0.00011 mSv/year. From the measurements inside and outside the cesium-137 room, the percentage of radiation shielding effectiveness can be calculated. In the operator's room the effectiveness of the shield is 94.40%; in the inventory room the effectiveness of the shield is 98.44%; in the product test lab room the effectiveness is 98.44%; in the parking lot the effectiveness is obtained at 98.8%. Based on Perka BAPETEN No.4 Year 2013, the data shows that the value of radiation exposure around the cesium-137 room at BPFK Medan is still within safe limits.
    URI
    https://repositori.usu.ac.id/handle/123456789/101529
    Collections
    • Undergraduate Theses [1307]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV