• Login
    View Item 
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Civil Engineering
    • Master Theses
    • View Item
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Civil Engineering
    • Master Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Pengaruh Metode Pemodelan Panel Zone Struktur Baja SRPMK terhadap Hasil Simulasi Keruntuhan Akibat Getaran Gempa

    The Influence of SRPMK Steel Structure Panel Zone Modeling Method on Collapse Simulation Results Due to Earthquake Vibrations

    Thumbnail
    View/Open
    Cover (420.5Kb)
    Fulltext (1.625Mb)
    Date
    2024
    Author
    Rasuna, T Yuan
    Advisor(s)
    Tarigan, Johannes
    Nursyamsi
    Metadata
    Show full item record
    Abstract
    This research aims to determine whether the panel zone effect has an influence when using the Indonesian earthquake zone based on SNI 1726:2019 in the seismic design category D in the city of Medan using a special moment resisting frame system (SRPMK) and priority earthquake risk factor 4 with conditions. soft ground. In this research, a comparison will be made of 7-story and 10-story steel structure buildings using zone panels and without zone panels so that the results of zone panels can be found for earthquakes in Indonesia. The results of the structural check show that the 7 and 10 storey building structures using zone panels and without zone panels meet earthquake resistance reliability with SNI 1726:2019 regulations and fulfill the Strong Column-Weak Beam (SC-WB) SNI 7860:2020 concept for buildings without using zone panels. more rigid than using zone panels. The results of the comparative analysis of the roof displacement of a 7-story building using zone panels are 9.23% greater in the X direction 10.63% and Y direction 9.25% compared to a 10-story building without zone panels. Comparison results of the story drift ratio for a 7-story building using a panel zone that is 9.21% larger in the X direction and 11.55% in the Y direction compared to a 7-story building without a zone panel, for a 10-story building using a larger panel zone in the and Y direction 9.25% compared to a 10-story building without zone panels. These results show that the use of zone panels in a steel structure will make a rigid structure become semi-rigid.
    URI
    https://repositori.usu.ac.id/handle/123456789/101567
    Collections
    • Master Theses [246]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV