    Rancang Bangun dan Analisis Persentase Kesalahan Alat Ukur Tahanan Tanah Berbasis IoT Menggunakan Aplikasi Blynk

    Design Build and Analysis of Error Percentage of IoT-Based Soil Resistance Measuring Instrument Using Blynk Application

    Thumbnail
    View/Open
    Cover (786.3Kb)
    Fulltext (2.347Mb)
    Date
    2024
    Author
    Anugrah, Ikhsan
    Advisor(s)
    Siregar, Yulianta
    Metadata
    Show full item record
    Abstract
    The Soil resistance measurement is essential to determine the resistance value of the soil. Due to frequent human errors and limited measurement parameters in standard earth testers, a study was conducted to design and develop an IoT-based soil resistance measuring device. This device is equipped with soil moisture measurement using the ESP32 microcontroller, and the results can be displayed via a smartphone. Using a comparative method, the measurement results were analyzed against a standard measuring device, the Kyoritsu Earth Tester, based on testing variations in soil conditions (dry and wet) and electrode depth variations of 10 cm, 20 cm, 30 cm, and 40 cm. The study results show that the designed earth tester can display battery voltage, soil moisture, and soil resistance in real time through the Blynk app on a smartphone. The best error percentage in the measurement results was observed in dry soil conditions with 7% moisture content and a 10 cm electrode depth, with a 0% error percentage. The least accurate results were found in wet soil conditions with 61% moisture content and a 40 cm electrode depth, with an error percentage of 76%. The average error percentage from the measurements was 32%, with the device having an accuracy of 68%. The effect of electrode depth on error percentage showed that the deeper the electrode is buried, the higher the error percentage tends to increase. According to the IEC 61557-5 standard, measurements in dry soil with 7% moisture content at a 10 cm depth, and in wet soil with 61% moisture content at a 10 cm depth, met the specified standard.
    URI
    https://repositori.usu.ac.id/handle/123456789/101776
    Collections
    • Undergraduate Theses [1461]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV