• Login
    View Item 
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Environmental Engineering
    • Undergraduate Theses
    • View Item
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Environmental Engineering
    • Undergraduate Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Analisis dan Pemetaan Tingkat Kebisingan Akibat Aktivitas Produksi Industri Tapioka PT. Hari Sejahtera

    Analysis and Mapping of Noise Levels Due to Tapioca Industry Production Activities of PT. Hari Sejahtera

    Thumbnail
    View/Open
    Cover (1.858Mb)
    Fulltext (9.020Mb)
    Date
    2025
    Author
    Zendrato, Khairattun Nur
    Advisor(s)
    Suryati, Isra
    Sari, Yasmine Anggia
    Metadata
    Show full item record
    Abstract
    PT. Hari Sejahtera Tapioka is a prominent industry engaged in the production of tapioca flour. However, the utilization of machinery in this industry has resulted in elevated noise levels, posing a potential threat to worker safety. According to Permenaker No. 5 of 2018, the permissible noise level standard for occupational safety and health is 85 dB(A), with a maximum exposure duration of 8 hours. To assess the noise level, a comprehensive survey was administered to 100% of production department personnel. The recommended course of action involves measuring and mapping the noise level to inform initial decision-making. Noise level measurements were conducted using a Sound Level Meter (SLM), in compliance with the noise monitoring regulation stipulated in Ministry of Environment and Forestry No. 48 of 1996. This regulation mandates noise monitoring at 7 intervals during a 24-hour period, encompassing both overall and operational assessments. Based on the applicable standard, the highest recorded noise level (LSM) at PT Hari Sejahtera Tapioka was 88.86 dB(A) at point 13 on Wednesday, while the lowest noise level was 51.36 dB(A) at point 22. The research findings indicate that noise levels on working days exceed those on holidays. Moreover, the strategic deployment of barriers featuring ¾ acoustic panels on the ceiling and rockwool on the walls can effectively reduce noise levels by up to 50% in the production room.
    URI
    https://repositori.usu.ac.id/handle/123456789/102364
    Collections
    • Undergraduate Theses [380]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV