    Evaluasi Kinerja Instalasi Pengolahan Air Limbah Rumah Sakit Pabatu, Tebing Tinggi, Sumatera Utara

    Performance Evaluation of the Wastewater Treatment Installation of Pabatu Hospital, Tebing Tinggi, North Sumatra

    Thumbnail
    View/Open
    Cover (376.0Kb)
    Fulltext (3.445Mb)
    Date
    2024
    Author
    Alakbar, M Fikri Rafa
    Advisor(s)
    Husin, Amir
    Nasution, Zaid Perdana
    Metadata
    Show full item record
    Abstract
    In January 2024, Pabatu Hospital, Tebing Tinggi, generated wastewater with a COD parameter of 60.71 mg/L. The wastewater treatment plant (WWTP) produces 109.09 m³/day, so an evaluation is necessary to assess the quality of the treated wastewater. The purpose of this research is to evaluate the design used in the wastewater treatment of Pabatu Hospital, Tebing Tinggi, and to determine the performance of each unit in the WWTP. This research was conducted at Pabatu Hospital, Tebing Tinggi, in May 2024. The type of research is comparative, which compares the output of wastewater from each treatment unit with the quality standards permitted by the government, referring to the Minister of Environment Decree No. 5 of 2014 concerning wastewater quality standards, Annex XLVI, and also evaluates the design by comparing design criteria. The data processing technique includes calculating the capacity of the WWTP and the design of each WWTP unit by comparing the design criteria and calculating the effectiveness of the treatment units in the hospital WWTP, indicated by the percentage of pollutant removal. The research results show a significant reduction in parameters, with BOD decreasing from 20.35 mg/L at the inlet to 3.6 mg/L at the outlet, COD from 67.1 mg/L at the inlet to 11.9 mg/L at the outlet, and TSS from 18 mg/L at the inlet to 4 mg/L at the outlet. The overall removal efficiency is >80%. The design and operation of the hospital's WWTP generally show good results in reducing the pollutant load from the wastewater, although the Aeration, Aerobic I, and Sedimentation stages have not yet reached the target removal efficiency based on existing references. These areas require further optimization. For example, the equalization unit needs detention time optimization, as it only allows for 3.48 hours, whereas the design criteria for this unit require a detention time of 6 hours. The sedimentation tank also requires a redesign or adjustment in flow rate to ensure the residence time aligns with the design criteria range of 2-4 hours.
    URI
    https://repositori.usu.ac.id/handle/123456789/103350
    Collections
    • Undergraduate Theses [380]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV