    Analisa Kadar Fluorida (F-) dan Kekeruhan pada Air Minum dan Air Bersih di Balai Teknik Kesehatan Lingkungan dan Pengendalian Penyakit (BTKLPP) Kelas 1 Medan

    View/Open
    Fulltext (1.206Mb)
    Date
    2019
    Author
    Sihombing, Ika F
    Advisor(s)
    Sinaga, M. Zulham Efendi
    Metadata
    Show full item record
    Abstract
    Telah dilakukan analisa kadar fluorida (F-) dan kekeruhan pada air minum dan air bersih di Balai Teknik Kesehatan Lingkungan dan Pengendalian Penyakit (BTKLPP) Kelas 1 Medan. Analisa kadar fluorida dilakukan dengan menggunakan metode spektrofotometri pada panjang gelombang 580 nm dan analisa kekeruhan dilakukan dengan metode turbidimetri. Hasil analisa kadar fluorida untuk sampel air minum dan air bersih diperoleh hasil sampel 1 : 0,74 mg/L dan <0,02 mg/L, sampel 2 : 0,06 mg/L dan <0,02 mg/L. Kadar kekeruhan diperoleh hasil sampel 1 : 1,14 NTU dan 1,01 NTU, sampel 2 : 1,35 NTU dan 1,26 NTU. Dari data di atas menunjukkan kadar fluorida dan kekeruhan pada air minum memenuhi baku mutu sesuai dengan 492/Menkes/Per/IV/2010 sebesar 1,5 mg/L dan 5 NTU. Pada air bersih memenuhi baku mutu sesuai dengan 416/Menkes/Per/IX/1990 sebesar 1,5 mg/L dan 25 NTU.
     
    Fluoride level (F-) analysis and turbidity in drinking water and clean water have been carried out at the Balai Teknik Kesehatan Lingkungan dan Pengendalian Penyakit Kelas 1 Medan. Fluoride level analysis was carried out using the spectrophotometric method on wavelength 580 nm and turbidity analysis was carried out using the turbidimetry method. The analysis of fluoride content for drinking water and clean water samples, the results of sample 1: 0.74 mg / L and <0.02 mg / L, sample 2: 0.06 mg / L and <0.02 mg / L . The turbidity level obtained from the sample 1: 1.14 NTU and 1.01 NTU, sample 2: 1.35 NTU and 1.26 NTU. From the data above shows fluoride levels and turbidity in drinking water meet quality standards in accordance with 492 / Menkes / Per / IV / 2010 of 1.5 mg / L and 5 NTU. Clean water meets quality standards in accordance with 416 / Menkes / Per / IX / 1990 at 1.5 mg / L and 25 NTU.

    URI
    http://repositori.usu.ac.id/handle/123456789/22643
    Collections
    • Diploma Papers [1126]

    Repositori Institusi Universitas Sumatera Utara - 2025

    Universitas Sumatera Utara

    Perpustakaan

    Resource Guide

    Katalog Perpustakaan

    Journal Elektronik Berlangganan

    Buku Elektronik Berlangganan

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara - 2025

    Universitas Sumatera Utara

    Perpustakaan

    Resource Guide

    Katalog Perpustakaan

    Journal Elektronik Berlangganan

    Buku Elektronik Berlangganan

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV