Analisa Kadar Fluorida (F-) dan Kekeruhan pada Air Minum dan Air Bersih di Balai Teknik Kesehatan Lingkungan dan Pengendalian Penyakit (BTKLPP) Kelas 1 Medan
| dc.contributor.advisor | Sinaga, M. Zulham Efendi | |
| dc.contributor.author | Sihombing, Ika F | |
| dc.date.accessioned | 2020-01-15T04:27:11Z | |
| dc.date.available | 2020-01-15T04:27:11Z | |
| dc.date.issued | 2019 | |
| dc.identifier.uri | http://repositori.usu.ac.id/handle/123456789/22643 | |
| dc.description.abstract | Telah dilakukan analisa kadar fluorida (F-) dan kekeruhan pada air minum dan air bersih di Balai Teknik Kesehatan Lingkungan dan Pengendalian Penyakit (BTKLPP) Kelas 1 Medan. Analisa kadar fluorida dilakukan dengan menggunakan metode spektrofotometri pada panjang gelombang 580 nm dan analisa kekeruhan dilakukan dengan metode turbidimetri. Hasil analisa kadar fluorida untuk sampel air minum dan air bersih diperoleh hasil sampel 1 : 0,74 mg/L dan <0,02 mg/L, sampel 2 : 0,06 mg/L dan <0,02 mg/L. Kadar kekeruhan diperoleh hasil sampel 1 : 1,14 NTU dan 1,01 NTU, sampel 2 : 1,35 NTU dan 1,26 NTU. Dari data di atas menunjukkan kadar fluorida dan kekeruhan pada air minum memenuhi baku mutu sesuai dengan 492/Menkes/Per/IV/2010 sebesar 1,5 mg/L dan 5 NTU. Pada air bersih memenuhi baku mutu sesuai dengan 416/Menkes/Per/IX/1990 sebesar 1,5 mg/L dan 25 NTU. | en_US |
| dc.description.abstract | Fluoride level (F-) analysis and turbidity in drinking water and clean water have been carried out at the Balai Teknik Kesehatan Lingkungan dan Pengendalian Penyakit Kelas 1 Medan. Fluoride level analysis was carried out using the spectrophotometric method on wavelength 580 nm and turbidity analysis was carried out using the turbidimetry method. The analysis of fluoride content for drinking water and clean water samples, the results of sample 1: 0.74 mg / L and <0.02 mg / L, sample 2: 0.06 mg / L and <0.02 mg / L . The turbidity level obtained from the sample 1: 1.14 NTU and 1.01 NTU, sample 2: 1.35 NTU and 1.26 NTU. From the data above shows fluoride levels and turbidity in drinking water meet quality standards in accordance with 492 / Menkes / Per / IV / 2010 of 1.5 mg / L and 5 NTU. Clean water meets quality standards in accordance with 416 / Menkes / Per / IX / 1990 at 1.5 mg / L and 25 NTU. | en_US |
| dc.language.iso | id | en_US |
| dc.publisher | Universitas Sumatera Utara | en_US |
| dc.subject | Kadar Fluorida (F) | en_US |
| dc.title | Analisa Kadar Fluorida (F-) dan Kekeruhan pada Air Minum dan Air Bersih di Balai Teknik Kesehatan Lingkungan dan Pengendalian Penyakit (BTKLPP) Kelas 1 Medan | en_US |
| dc.type | Thesis | en_US |
| dc.identifier.nim | NIM162401060 | |
| dc.description.pages | 54 Halaman | en_US |
| dc.description.type | Kertas Karya Diploma | en_US |