• Login
    View Item 
    •   USU-IR Home
    • Faculty of Mathematics and Natural Sciences
    • Department of Physics
    • Master Theses
    • View Item
    •   USU-IR Home
    • Faculty of Mathematics and Natural Sciences
    • Department of Physics
    • Master Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Pembuatan dan Pengujian Phantom Tulang Tungkai Atas Berbasis CaCO3, CaCl2, NaCl, KOH, dengan Uji Hounsfield Unit (HU) pada Modalitas CT.Scan

    View/Open
    Fulltext (3.262Mb)
    Date
    2020
    Author
    Sihombing, Manumpan
    Advisor(s)
    Humaidi, Syahrul
    Tarigan, Kerista
    Metadata
    Show full item record
    Abstract
    Penggantian phantom femur manusia dengan menggunakan CaCO3, CaCl2, NaCl, KOH + semen putih berhasil dibuat. Penggantian phantom femur pada manusia dibuat dengan 3 varian komposisi (x = 0,3 dan y = 0,67, x = 0,34 dan y = 0,63, dan x = 0,4 dan y = 0,57)yang ditandai dengan x sebagai CaCO3dan y sebagai semen putih. Phantom pengganti tulang paha diuji menggunakan modalitas CT-SCAN merek GE / Optima 660 dengan 3 variasi potensial berbeda yaitu 80 kV, 100 kV, dan 120 kV untuk melihat unit Hounsfield (HU) dalam sampel uji. Melalui uji CT-SCAN, HU tertinggi sebesar 2016, yang ditemukan pada phantom pengganti x = 0,3 dan y = 0,67 dengan beda potensial 80 kV dan HU terendah adalah 904 yang ditemukan pada variasi phantom pengganti x = 0,4 dan y = 0,57 dengan perbedaan potensial sebesar 120 kV beda, sedangkan tulang HU secara umum sebesar +/- 1000.
     
    Phantom replacement of femur based on human CaCO3, CaCl2, NaCl, KOH + white cement successfully made. Phantom replacement of the femur in humans is made with 3 variants of composition (x = 0.3 and y = 0.67, x = 0.34 and y = 0.63, and x = 0.4 and y = 0.57) namely x is CaCO3 and y is white cement. Thigh replacement phantom was tested using the GE / Optima 660 brand CT-SCAN with 3 potential different variations namely 80 kV, 100 kV, and 120 kV to see Hounsfield units (HU) in the test sample. Through CT-SCAN test, the highest HU is 2016, which is found in substitute phantom x = 0.3 and y = 0.67 with a potential difference of 80 kV and the lowest HU is 904 found in the replacement phantom variation x = 0.4 and y = 0.57 with 120 kV potential difference, while HU bone in general is +/- 1000.

    URI
    http://repositori.usu.ac.id/handle/123456789/24889
    Collections
    • Master Theses [307]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV