    Evaluasi Pencahayaan dan Penghawaan pada Ruang Rawat Inap Pasien Rumah Sakit (Studi Kasus: Ruang Rawat Inap Pasien Rumah Sakit Pendidikan Universitas Sumatera Utara)

    View/Open
    Fulltext (7.622Mb)
    Date
    2020
    Author
    Naibaho, Titi Santi Evriyanta
    Advisor(s)
    Aulia, Dwira Nirfalini
    Nasution, Achmad Delianur
    Metadata
    Show full item record
    Abstract
    Ruang rawat inap pasien sebuah rumah sakit merupakan salah satu wujud fasilitas fisik yang penting keberadaannya bagi pelayanan pasien. Kondisi lingkungan fisik ruang rawat inap akan mempengaruhi psikologis pasien. Pencahayaan dan penghawaan dalam ruang rawat inap pasien dapat mempengaruhi kenyamanan pasien selama menjalani perawatan dan berpengaruh bagi kelancaran paramedis dalam menjalankan aktivitas. Terkait dengan hal ini, pencahayaan dan penghawaan baik alami ataupun buatan di dalam ruang rawat inap pasien sebaiknya perlu diperhitungkan agar tidak menimbulkan pemborosan energi. Hemat energi perlu dilakukan terutama pada pemakaian energi yang tak terbarukan, mengigat sumbernya yang semakin terbatas. Penelitian ini bertujuan untuk mengevaluasi pencahayaan dan penghawaan pada Ruang Rawat Inap Pasien di Rumah Sakit Pendidikan Universitas Sumatera Utara. Sehingga nantinya akan dapat diketahui apakah suatu ruang rawat inap pasien sudah memenuhi standar pencahayaan dan penghawaan yang berlaku. Hasil pengukuran suhu rata-rata penghawaan ruang rawat inap pasien ruangan dengan kipas angin berkisar sekitar 30,2° C dan 27,9° C untuk ruangan ber-AC. Hasil komparasi dengan teori Lippsmeier menunjukkan bahwa suhu 27,9° C termasuk kedalam kondisi nyaman optimal dengan batas maksimum sampai 28° C dan suhu 30,2° C termasuk kedalam kondisi hangat nyaman karena masih masuk dalam batas kategori sebesar 28°C - 31°C. Hasil pengukuran tingkat pencahayaan dengan menggunakan Light Meter diperoleh pencahayaan alami pada pagi hari 241 LUX, pada siang hari 390 LUX dan pada sore hari sebesar 747 LUX. Sedangkan untuk tingkat pencahayaan buatan konstan di angka 1.240 LUX. Hasil komparasi dengan nilai minimum standar rekomendasi SNI 03-6197-2000 menunjukkan tingkat pencahayaan buatan dan pencahayaan alami pada siang dan sore hari pada ruang rawat inap pasien sudah memenuhi nilai minimum standar rekomendasi. Sedangkan tingkat pencahayaan alami pada pagi hari masih belum memenuhi nilai minimum standar rekomendasi yakni 250 LUX.
     
    Inpatient wards of a hospital is one of the important physical facilities for patients since the condition of inpatient wards will influence their psychology. Lighting and aeration in inpatient wards can influence patients comfort during their treatment and can also influence health care providers’ smoothness in doing their tasks. Therefore, natural or artificial lighting and aeration in inpatient wards should be carefully considered in order to save energy. Energy saving should be done, especially in non-renewal energy, due to its limited source. The objective of the research was to evaluate lighting and aeration in the Inpatient Wards of the Education Hospital, University of Sumatera Utara, so that it could be found out whether the lighting and aeration of the Inpatient Wards had fulfilled the requirements. The result of the average aeration of the Inpatient Wards, using fans, was about 30.2oC and in air conditioned wards was 27.9oC. The result of the comparison with Lippsmeier theory showed that the temperature of 27.9oC and 30.2oC was considered optimally comfortable condition up to the maximum of 28oC, and the temperature of 30.2oC was considered warmly comfortable condition since it was included in the category of 28oC-31oC. The result of measurement of the level of lighting, using Light Meter, showed that natural lighting in the morning was 241 LUX, at noon was 390 LUX, and in the afternoon was 747 LUX, while for the artificial constant lighting was 1.240 LUX. The result of comparison with the minimum value of SNI 03-6197-2000 recommended standard showed that the level of artificial and natural lighting in the Inpatient Wards in the morning and in the afternoon had fulfilled the minimum value of the recommended standard, while the level of natural lighting in the morning had not fulfilled the minimum value of the recommended standard of 250 LUX.

    URI
    http://repositori.usu.ac.id/handle/123456789/24985
    Collections
    • Master Theses [254]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV