Show simple item record

dc.contributor.advisorWarman, Aditia
dc.contributor.authorSimarmata, Meisy Resguvani
dc.date.accessioned2020-09-10T01:47:43Z
dc.date.available2020-09-10T01:47:43Z
dc.date.issued2020
dc.identifier.urihttp://repositori.usu.ac.id/handle/123456789/27369
dc.description.abstractPulse oximetry is a tool with a method without injuring parts of the body (non-invasive) to measure levels of hemoglobin (Hb) in the blood. Tools pulse oximetry using different wavelengths of red light (660 nm) and infrared light (940 nm) are captured by the sensor detection after passing through the veins and capillaries at the tip of the index finger. Arduino is used to process the data, while the LCD is used to display the measurement results of the sensor. Data from the detection sensor is sent to the microcontroller and then directly to the LCD display. The microcontroller, the data is processed and then processed to obtain the data of oxygen saturation (SpO2). The normal range of oxygen saturation in the blood is above 70%. Hemoglobin test results with tools made to have an error rate of 1.5% compared to the standard measuring devices.en_US
dc.description.abstractPulse oximetry is a tool with a method without injuring parts of the body (non-invasive) to measure levels of hemoglobin (Hb) in the blood. Tools pulse oximetry using different wavelengths of red light (660 nm) and infrared light (940 nm) are captured by the sensor detection after passing through the veins and capillaries at the tip of the index finger. Arduino is used to process the data, while the LCD is used to display the measurement results of the sensor. Data from the detection sensor is sent to the microcontroller and then directly to the LCD display. The microcontroller, the data is processed and then processed to obtain the data of oxygen saturation (SpO2). The normal range of oxygen saturation in the blood is above 70%. Hemoglobin test results with tools made to have an error rate of 1.5% compared to the standard measuring devices.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectPulse Oximetryen_US
dc.subjectNon-invasiveen_US
dc.subjectMikrokontroleren_US
dc.titleRancang Bangun Pulse Oximetry Digital Berbasis Atmega328 dengan Buzzer Sebagai Alarm Diagnosa Abnormalen_US
dc.typeThesisen_US
dc.identifier.nimNIM172408084
dc.description.pages59 Halamanen_US
dc.description.typeKertas Karya Diplomaen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record