    Perancangan Alat Deteksi Suhu dan Asap dengan IoT Berbasis Mikrokontroler Atmega328P

    View/Open
    Fulltext (1.696Mb)
    Date
    2020
    Author
    Panjaitan, Sofi Octavia
    Advisor(s)
    Warman, Aditia
    Metadata
    Show full item record
    Abstract
    Sistem akan mengirimkan peringatan dalam bentuk pesan singkat melalui GMAIL ketika sensor membaca kepekatan gas dan suhu panas ruangan masuk dalam level bahaya. Sensor bekerja ketika sistem membaca suhu ruangan diatas 23°C sistem akan mengirimkan peringatan GMAIL “terlalu banyak asap di area rumah segera cek” dan membunyikan buzzer. Prototipe sistem peringatan dan pemadam kebakaran ruangan mengaplikasikan sensor gas (MQ-2) untuk mendeteksi asap dan sensor suhu (DS18B20) untuk mendeteksi suhu dalam ruangan. Dari pengujian fungsionalitas disimpulkan komponen-komponen yang terhubung dengan prototipe sistem telah berfungsi dengan baik. Dari pengujian usability disimpulkan prototype sistem mudah digunakan dan dapat mendeteksi kebakaran, sama seperti sensor suhu sensor asap bekerja ketika sistem membaca tegangan ruangan diatas 3V sistem akan mengirimkan peringatan GMAIL “Suhu terlalu tinggi disekitar rumah harap cek kondisi rumah” dan membunyikan buzzer.
     
    The system will send a warning in the form of a short message via GMAIL when the sensor reads the gas density and indoor heat temperature into a danger level. The sensor works when the system reads the room temperature above 23 ° C, the system will send a GMAIL warning "too much smoke in the area of the house, check immediately" and sound a buzzer. The room fire warning and extinguishing system prototype applies a gas sensor (MQ-2) to detect smoke and a temperature sensor (DS18B20) to detect indoor temperature. From the functionality testing, it is concluded that the components connected to the system prototype are functioning properly. From the usability test, it is concluded that the prototype system is easy to use and can detect fires, just as the smoke sensor temperature sensor works when the system reads room voltage above 3V the system will send a GMAIL warning "The temperature is too high around the house, please check the condition of the house" and sound the buzzer.

    URI
    http://repositori.usu.ac.id/handle/123456789/29496
    Collections
    • Diploma Papers (Metrology and Instrumentation) [402]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV