Penentuan Kadar Air di dalam Gas Alam di PT Pertamina Ep Region Sumatera Field Pangkalan Susu
View/ Open
Date
2008Author
Tarigan, Sri dewi Agustina
Advisor(s)
Manik, Sudestry
Metadata
Show full item recordAbstract
Naturally, water vapor content is found in natural gas which have variation value depended to the natural gas field. Determination procedure of water vapor content be done the natural gas to know result of water vapor content value. So the result can be comparison with limit standart. So we can know the quality of natural gas. Water vapor content more than standart have bad effect for that quality of natural gas and transmisi pipe. Maximum standart of water content in natural gas determined about < 10 lb/mmScf. but water content which found in the field of WP 302 is 9,0 lb/mmScf, and WP 303 is 9,4 lb/mmScf, and CN-II is 8,6 lb/mmScf, and MET-PTP is 9,2 lb/mmScf.
Collections