dc.description.abstract | Giving phospate into bait boiler water have a purpose to prevent
korosi and deposit formation at boiler wall. Korosi and phospate
formation are caused by chemical process of calsium and magnesium in
the boiler water.
If level of phospate is too high or low in bait boiler water, it will
cause korosi and deposit formation that can cause heat wich not flatten at
boiler and the energy that is needed at boiler is higher to produce steam.
From analysis result is obtained level of phospate that is measured
energy 3 hours that fulfill the rules specified by PT. Toba Pulp Lestari,
Tbk Porsea equal is 5-10 ppm but the result of analysis by 5-8 ppm. | en_US |