Show full item recordAbstract
Analysis of the levels of chemical oxygen demand (COD) in wastewater hospitals
using closed reflux titrimetric method. Has done heating samples of hospital waste
that passes through the refineries for 2 hours at a temperature of 148 ° C in COD
Thermoreactor obtained that level of COD in waste water that is the first week of
52.33 mg / L, the second week of 63.62 mg / L, the third week 68.42 mg / L, the
fourth week of 58.43 mg / L and the fifth week of 46.54 mg / L. From the results
obtained show that the hospital waste water does not exceed the maximum
standards set by KEP-58 / MENLH / 12/1995 concerning water quality standards
of hospital waste