dc.contributor.advisor | Andriayani | |
dc.contributor.author | Sahab, Muhammad Fahmi | |
dc.date.accessioned | 2022-12-12T14:22:07Z | |
dc.date.available | 2022-12-12T14:22:07Z | |
dc.date.issued | 2015 | |
dc.identifier.uri | https://repositori.usu.ac.id/handle/123456789/72815 | |
dc.description.abstract | Analysis of the levels of chemical oxygen demand (COD) in wastewater hospitals
using closed reflux titrimetric method. Has done heating samples of hospital waste
that passes through the refineries for 2 hours at a temperature of 148 ° C in COD
Thermoreactor obtained that level of COD in waste water that is the first week of
52.33 mg / L, the second week of 63.62 mg / L, the third week 68.42 mg / L, the
fourth week of 58.43 mg / L and the fifth week of 46.54 mg / L. From the results
obtained show that the hospital waste water does not exceed the maximum
standards set by KEP-58 / MENLH / 12/1995 concerning water quality standards
of hospital waste | en_US |
dc.language.iso | id | en_US |
dc.publisher | Universitas Sumatera Utara | en_US |
dc.title | Analisa Kadar Chemical Oxygen Demand (COD) pada Air Limbah Rumah Sakit dengan Metode Titrimetri Refluks Tertutup di Laboratorium Sucofindo | en_US |
dc.type | Thesis | en_US |
dc.identifier.nim | NIM122401127 | |
dc.identifier.nidn | NIDN0005036903 | |
dc.identifier.kodeprodi | KODEPRODI47401#Kimia | |
dc.description.pages | 36 Halaman | en_US |
dc.description.type | Kertas Karya Diploma | en_US |