Analisa Kadar Fosfat pada Beberapa Air Sungai di Kota Medan Secara Spektrofotometri UV-Visible
View/ Open
Date
2014Author
Purba, Anni Rahmani
Advisor(s)
Pasaribu, Nurhaida
Metadata
Show full item recordAbstract
Analysis of phosphate value have been done from the river water of
Amplas river have been taken from Amplas area, the water of Deli river have been
taken from Juanda area and also the water of Babura river have been taken from
Padang Bulan area by Spektrofotometri UV - Visible with the length of wave is
880 nm. The phosphate value of Amplas river water sample is upstream 1 is
0,14255 mg/L, upstream 2 is 0, 14315 mg/L, downstream 1 is 0,1886 mg/L,
downstream 2 is 0, 1899 mg/L, in Deli river which is located in Juanda area is
upstream 1 is 0,0903 mg/L, upstream 2 is 0,0944 mg/L, downstream 1 is 0,1104
mg/L, downstream 2 is 0,1121 mg/L. And in Babura river which is located in
Padang Bulan area is upstream 1 is 0,1338 mg/L, upstream 2 is 0,1190 mg/L,
downstream 1 is 0,1257 mg/L and downstream 2 is 0,295 mg/L.
According government rules number 82 years 2001, from analysis of phosphate
value which taken from third the river thatboth of them still comply the
normative level standard of water class II (0,2 mg/L) which used to water and etc.
Collections
- Diploma Papers [1126]