dc.description.abstractThere are three parameters, those are parameter of chemistry, parameter of physic, parameter of biology to determined water quality. In this study, used parameter of chemistry to determine nikel (Ni) is done with Inductively Couple Plasma (ICP) method and titration of complexiometry method, where for the result of nikel (Ni) levels made in mg/L. The analisis result are gotten used Inductively Couple Plasma (ICP) method for nikel : 0.33671 mg/L and used titration of complexiometry method for nikel : 2935.5 mg/L. From the analysis result are gotten that nikel levels in drinks water had been over than normal range that according to PERMENKES 492/MENKES/PER/IV/2010, where standart quality of nikel in drinks water is 0,07 mg/Len_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.titlePerbandingan Hasil Pengukuran Kadar Nikel dengan Metode ICP (Inductively Couple Plasma) dan Titrasi Kompleksiometri pada Sampel Air Minumen_US
dc.typeThesisen_US
dc.identifier.nimNIM102401062
dc.identifier.nidnNIDN8836140017
dc.identifier.kodeprodiKODEPRODI47401#Kimia
dc.description.pages64 Halamanen_US
dc.description.typeKertas Karya Diplomaen_US