Analisa Kandungan Chemical Oxygen Demand (COD) pada Limbah Cair dari Inlet dan Outlet Cooling Pond PT Pertamina Geothermal Energy Area Sibayak
View/ Open
Date
2015Author
Karo, Dhella Theresia Br
Advisor(s)
Alfian, Zul
Metadata
Show full item recordAbstract
COD (Chemical Oxygen Demand) is a parameter that indicates in many organic
compounds that can be oxidized in wastewater. The organic compound to be
oxidized by an oxidizing reagent. COD concentration of effluent at the inlet and
outlet cooling pond PT PERTAMINA GEOTHERMAL AREA ENENRGY
Sibayak has been done, where the methods used to measure the levels of COD in
waste water liquid at the inlet and outlet cooling pond that is using titrimetric
method. COD analysis results obtained in the first week until the fourth week of
each is as follows, Week I: inlet 241.28 mg / l, outlets 79.04 mg / l; Week II: inlet
287.04 mg / l, outlet 128.96 mg / l; week III: inlet 224.64 mg / l, outlets 74.88 mg
/ l; Week IV: inlet 224.64 mg / l, outlet 141.44 mg / l. And the results of the
analysis none of COD at the outlet exceeds the standard limit set by the Minister
of the Environment.
Collections