Pengaruh Laju Alir dan Tekanan Kolom terhadap Proses Pemurnian Argon dari Liquid Oksigen pada Unit Destilasi di PT. Aneka Gas Industri Medan
View/ Open
Date
2014Author
Tanjung, Abdul Azis
Advisor(s)
Marpongahtun
Metadata
Show full item recordAbstract
Argon purification process has been carried out on the liquid Oxygen in
the PT. Aneka Gas Industri Medan which Oxygen rich content of Argon separated
in Crude Argon System continuously until the purity Oxygen reaches 99.99%
conducted distillation column. The separation process depends on the flow rate,
temperature, and pressure. The results of the data obtained showed that the purity
of Argon which reached 99.99% was obtained at a pressure of 5.35 kg cm-2 and a
flow rate of 6480 m hour -1. In the pressure < 5,35 kg cm-2 (5,02 – 5,22 kg cm-2)
and flow rate < 6480 m hour-1 (6380 – 6460 m hour-1). Argon purity of was
obtained around 99,95 – 99,98%. In the pressure > of 5,35 kg cm-2 (5,44 – 5,80 kg
cm
-2) and flow rate > 6480 m hour-1 (6500 – 6650 m hour-1). Argon purity of was
obtained around 99,97 – 99,91%.