dc.description.abstract | Analyses have been performed to determine the level of Chemical Oxygen
Demand and Biological Oxygen Demand by titration method, Oil / Fat with
gravimetric extraction-method on Liquid Fluid of Palm Oil Factory. By heating
for 2 hours at temperature 150oC done at COD Destruction Block then dititrasi
obtained COD A plant amounting to 96,384 mg / L, factory B as much 144,576
mg / L, factory C as much 160,64 mg / L, by incubation and then titrated Obtained
A plant BOD content of 0.4 mg / L with dilution 500 times, factory B of C as
much as 0.4 mg / L with dilution 1000 times, by drying, extracting and weighing
obtained Oil / A plant oil content of 19 mg / L, plant B as much as 14 mg / L,
factory C as much as 71 mg / L. From the above results, COD, BOD and Oil / Fat
content of factory A and B meet the quality standard, while the C plant content of
COD and BOD meet the quality standard, but the oil / fat content does not meet
the quality standard set by Permen / LH / 5/2014 On Wastewater Quality
Standards. | en_US |