dc.description.abstract | Purification of CO2 and H2S in the feed gas can be removed with a solution of
carbonate and diethanolamin. The values that determine the optimal absorption process
takes place in a solution that is specific gravity (SG),% K2CO3,% KHCO3, K2CO3
equivalence, % DEA in lean carbonate, % carbonate in the lean DEA, % DEA, factor
convert, foaming test, collapse time, and particulate matter. Value % K2CO3, %
KHCO3, equivalence of K2CO3, % DEA in lean carbonate, % carbonate in the lean
DEA, % DEA, factor convert, determined by titration using HCl 0.1N Acydimetric as
pentiter substance and with the addition of phenolphthalein indicator, while the value of
SG, measured with a Hydrometer with archimedes principle of law, to the value
collapse time and foaming test was determined by means of tests and stopwatches, and
for particulate matter was determined by gravimetry. SG values, % K2CO3, % KHCO3,
equivalence of K2CO3, % DEA in lean carbonate, factor concert, foaming test, collapse
time, and particulate matter in the lean carbonate solution on 12,13,14th February 2014
are 1.2763, 1.2766, 1.2769, 21.19, 21.10, 21.17, 14.84, 14.54, 14.75, 31.45, 31.16,
31.37, -, 0.22 -, 0.32, 0.32, 0.32, 2, 2.25, 1.25, 1.45, 1.75, 0.6, -, 18, -. SG values,%
DEA,% carbonate in the lean DEA, a foaming formation, collapse time, and particulate
matter in solution diethanolamin lean on 12,13,14th February 2014 are 0.9912, 0.9903,
0.9912, 20.67, 21.01, 20.10, -, 12.11 , -, 1.0, 1.0, 1.0, 0.6, 0.5, 0.5, -, 19.5, -. | en_US |