    Pemanfaatan Cesium – 137 Sebagai Sumber Standar Kalibrasi pada Alat Ukur Radiasi Pen Dosimeter Type DMC 3000 Sn. 01A0734C

    View/Open
    Fulltext (3.996Mb)
    Date
    2022
    Author
    Ardilah
    Advisor(s)
    Maghfirah, Awan
    Metadata
    Show full item record
    Abstract
    Utilization ionizing radiation was contained in Government Regulation of the Republic of Indonesia No. 33 of 2007 concerning the safety and security provisions for the used of ionizing radiation refers to the provisions of the International Atomic Energy Agency (IAEA) and those issued by the International Commission on Radiological Protection. Government regulations regulated radiation safety for workers, the public, the environment as well as the safety of radioactive sources and inspectors in the use of nuclear power. The use of ionizing radiation sources for the purpose of radiation protection was required to measure the ionizing radiation. Radiation measuring instruments must be calibrated against reference measuring instruments traceable to the National Standard Laboratory in accordance with the amount of radiation being measured. One of the health instruments that needs to be calibrated was a pen dosimeter, it was a personal radiation protection measuring instrument used by radiation workers in radiology installations in hospitals. Radiation Measuring Instrument Calibration (AUR) has been carried out at the Health Facilities Security Agency, Medan. The calibration method used was the substitution method, the detector was irradiated in the gamma radiation field Cs – 137. Determination of calibration factor values and uncertainty to digital dosimeters used the Cesium standard – 137. In calibration, there was a standard deviation of obtained of 2,022% and a calibration factor of 1,02 μGy. An obtained measured dose and the dose read with a dose rate of 71.878114 μGy and an uncertainty value of 9.65% μGy. So that the digital dosimeter pen was good to use because it had a calibration factor value according to predetermined standards.
    URI
    https://repositori.usu.ac.id/handle/123456789/85576
    Collections
    • Undergraduate Theses [1309]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV