    Analisis Non Linier Perilaku Soft Storey pada Bangunan Ruko Padangsidimpuan dengan Memperhitungkan Bata sebagai Struktur

    View/Open
    Fulltext (4.960Mb)
    Date
    2016
    Author
    Harahap, Sahrul
    Advisor(s)
    Tarigan, Johannes
    Metadata
    Show full item record
    Abstract
    An earthquake of magnitude 76 on Richter scale struck the offshore of West Sumatera in 2009. It took place approximately 50 km to the Northwest from Padang The similar earthquake may very likely strike Padangsidimpuan as the principle of building construction in Padangsidimpuan uses the strong column weak beam as shown by the results of the visual field survey. Meanwhile, the principle in designing seismic-resistant building is the strong column weak beam. A failure in the column directly leads to a collapse on other structural components to which they are connected: even it is the limit state of collapse to the whole building One of the reasons why a building fails in an earthquake is the selection of soft story structure The research objective was to determine increase stiffness, maximum load capacity dhue to the brick as a load, the structure, structure the column confinement and structure based on SNI to a shop buildings in the city Padangsidimpan who reviewed the feasibility resistant to earthquakes. The method applied is the numeric simulation with finite element method. The result shows that the maximum base shear force of bricks in x axis is 1,268.12 kg (loading brick) 2,121 03 kg (brick as structure), 2,339.96 kg (confinement of brick column), and 2,924,36 kg (SNI standard brick). The result also shows that the maximum shear force base of bricks in x axis is 1,265 70 kg (loading brick) 6.048.19 kg (brick as structure). 6.395 49 kg (confinement of brick column), and 6,702. 15 kg (SN1 standard brick) The base shear force increases 1.75 times (brick as structure), 1.85 times (confinement of brick column), and 231 times (SNI standard brick) compared to the loading brick The stiffness increases 4.52 times (brick as structure), 5.08 times (confinement of brick. column), and 5.54 times (SNI standard brick)
    URI
    https://repositori.usu.ac.id/handle/123456789/85829
    Collections
    • Master Theses [246]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV