dc.contributor.advisorHasan, Syafruddin
dc.contributor.authorMilala, Yulianda Fitrah Br
dc.date.accessioned2023-09-26T06:47:40Z
dc.date.available2023-09-26T06:47:40Z
dc.date.issued2023
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/87853
dc.description.abstractThe continuity of electric power distribution needs to be considered in order to achieve the level of system reliability. The implementation of Fault Detection Isolation and Restoration (FDIR) is a smart way to improve system reliability and efficiency of distribution system operations. FDIR is a distribution network automation system that automatically performs the function of opening and closing the Load Break Switch (LBS) when a disturbance occurs by quickly detecting interference so that it can isolate and speed up fault recovery with load maneuvers. The purpose of this study is to determine the effect of FDIR application and analyze how SAIDI compares and duration of outages before and after FDIR application The results of the analysis show that there is a comparison of outage time and SAIDI before and after FDIR implementation. On the TT.05 feeder before FDIR, the average outage time was 22.15 minutes, after FDIR it was 10.70 minutes. Decreased average outage time by 51.745%. The average SAIDI before FDIR was 7.38333 minutes/customer, after FDIR was 3.56275 minutes/customer. The average decrease in SAIDI was 51.676%. In the DA.06 feeder before FDIR, the average outage time was 24.31 minutes, after FDIR it was 11.25 minutes. Decreased average outage time by 62.829%. While the average SAIDI before FDIR was 8.10417 minutes/customer, after FDIR it was 3.01243 minutes/customer. The average decrease in SAIDI was 53.723%. The magnitude of the percentage decrease shows the results of implementing the FDIR system. Effective FDIR implementation can significantly reduce outage duration and SAIDI to improve system reliability.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectFDIRen_US
dc.subjectLoad Maneuveren_US
dc.subjectRecovery Timeen_US
dc.subjectSAIDIen_US
dc.subjectSDGsen_US
dc.titleAnalisis Penerapan Fault Detection Isolation and Restoration untuk Penurunan Nilai Saidi (Studi Kasus PT PLN Unit Pelaksana Pengatur Distribusi Sumatera Utara)en_US
dc.typeThesisen_US
dc.identifier.nimNIM190402157
dc.identifier.nidnNIDN0001075904
dc.identifier.kodeprodiKODEPRODI20201#Teknik Elektro
dc.description.pages76 Halamanen_US
dc.description.typeSkripsi Sarjanaen_US