    Lighting is an important factor in designing space to support user comfort. Lack of light support in a room will cause activities in the room to be disrupted. To increase work effectiveness and work safety, operator work efficiency is assessed from the accuracy and thoroughness when looking at work. The lighting in the workshop area of production line I is 98 lux which is not in accordance with the standards of the Minister of Health Regulation No. 70 2016 concerning work environment health standards and requirements states that the standard light intensity level in factories or production areas working with machines is 300 lux. Inadequate lighting causes workers to experience eye fatigue when working at night so they experience a lack of focus at night. The results of measuring eye fatigue using the flicker fusion tool 18 out of 30 workers experienced eye fatigue. The data collection methodology in this study is using primary data and secondary data. Natural lighting in the workshop area of Production Line I is 260 lux and artificial lighting is 98 lux. The additional lights needed are as many as 10 lamps with a power of 250 watts to provide good lighting. The effect of lighting that does not meet standards is the disruption of the work of workers because it can cause eye fatigue. The company can replace the roof of the Production Line I workshop area with a skylight roof so that the light produced is more optimal. Companies should use an Automatic Light Intensity Control System so that the entire workshop area has good lighting intensity according to the same standard and there are no several points that have dim lighting.
    URI
    https://repositori.usu.ac.id/handle/123456789/87968
    Collections
    • Undergraduate Theses [1479]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV