Show simple item record

dc.contributor.advisorAnizar
dc.contributor.authorGinting, Yemima Kristina Br
dc.date.accessioned2023-10-04T04:14:53Z
dc.date.available2023-10-04T04:14:53Z
dc.date.issued2023
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/87968
dc.description.abstractLighting is an important factor in designing space to support user comfort. Lack of light support in a room will cause activities in the room to be disrupted. To increase work effectiveness and work safety, operator work efficiency is assessed from the accuracy and thoroughness when looking at work. The lighting in the workshop area of production line I is 98 lux which is not in accordance with the standards of the Minister of Health Regulation No. 70 2016 concerning work environment health standards and requirements states that the standard light intensity level in factories or production areas working with machines is 300 lux. Inadequate lighting causes workers to experience eye fatigue when working at night so they experience a lack of focus at night. The results of measuring eye fatigue using the flicker fusion tool 18 out of 30 workers experienced eye fatigue. The data collection methodology in this study is using primary data and secondary data. Natural lighting in the workshop area of Production Line I is 260 lux and artificial lighting is 98 lux. The additional lights needed are as many as 10 lamps with a power of 250 watts to provide good lighting. The effect of lighting that does not meet standards is the disruption of the work of workers because it can cause eye fatigue. The company can replace the roof of the Production Line I workshop area with a skylight roof so that the light produced is more optimal. Companies should use an Automatic Light Intensity Control System so that the entire workshop area has good lighting intensity according to the same standard and there are no several points that have dim lighting.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectNatural Lightingen_US
dc.subjectArtificial Lightingen_US
dc.subjectEye Fatigueen_US
dc.subjectLux Metersen_US
dc.subjectLighting SNIen_US
dc.subjectSDGsen_US
dc.titleAnalisis Pencahayaan dan Dampaknya terhadap Performansi Pekerja pada Area Workshop Jalur Produksi I di PT. Wijaya Karya Betonen_US
dc.typeThesisen_US
dc.identifier.nimNIM190403111
dc.identifier.nidnNIDN0002106802
dc.identifier.kodeprodiKODEPRODI26201#Teknik Industri
dc.description.pages80 Halamanen_US
dc.description.typeSkripsi Sarjanaen_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record