Show simple item record

dc.contributor.advisorZulkarnain, Hendra
dc.contributor.authorSihombing, Arie Michael Brisco
dc.date.accessioned2023-10-23T04:18:03Z
dc.date.available2023-10-23T04:18:03Z
dc.date.issued2023
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/88215
dc.description.abstractHigh voltages on the transmission lines cause electric and magnetic field effects that affect to the surrounding environment. If an electric field strikes a conductive object such as a roof, the roof becomes charged and creates an induced voltage between the roof and the ground. This study will observe the influence of the size of the house roof, the height of the roof trusses, and the distance from the roof to the conductor wire. This study also aims to observe the effect of induced voltage and current on the house roof on human safety. This study uses a version of the dimensional scale, with a ratio of 1: 7 from the actual size. The data obtained was analyzed to see the effect of the distance, the height of the trusses, and the size of the house roof. In a type 21 house with a truss height of 0,21 meters and a roof-to-wire distance of 1 meter, the measured voltage is 368 volts. If the truss height is increased to 0,29 meters, the measured voltage increases to 382 volts. If the roof-to-wire distance is increased to 1,07 meters, then the voltage on the roof of a type 21 house and a truss height of 0,21 drops to 319 volts, and the voltage on the roof of a house with a truss height of 0,29 drops to 343 volts. From the data obtained it can be concluded that the magnitude of the induced voltage is proportional to the size of the roof of the house and the height of the roof trusses, while the induced voltage is inversely proportional to the distance from the roof to the wire. The measured induction current does not reach 100 microamperes, so it is safe for human safety. The human body can act as a charge bridge between the roof and the ground, so that when touched by humans, the roof's charge runs out and the induced voltage is almost zero.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectHigh Voltage Transmissionen_US
dc.subjectInduced Voltageen_US
dc.subjectInduced Currenten_US
dc.subjectHouse Roofen_US
dc.subjectHuman Safetyen_US
dc.subjectSDGsen_US
dc.titleTegangan Induksi pada Atap Rumah di Bawah Saluran Transmisien_US
dc.typeThesisen_US
dc.identifier.nimNIM160402053
dc.identifier.nidnNIDN0014056104
dc.identifier.kodeprodiKODEPRODI20201#Teknik Elektro
dc.description.pages111 Halamanen_US
dc.description.typeSkripsi Sarjanaen_US