dc.description.abstractWater is one of the primary needs of humans, so it must be ensured to be safe and of good quality. One of the factors that indicates water quality is the presence of Escherichia coli bacteria in the water. Water can become contaminated with E. Coli bacteria if it is exposed to septic tanks that are not properly distanced from water sources. When water is contaminated with a significant amount of E. Coli bacteria, it becomes dangerous for use, as it can damage the walls of the small intestine and lead to symptoms such as stomach cramps, diarrhea mixed with blood, and vomiting. Electric disinfection is an efficient method for sterilizing water contaminated with E. Coli bacteria. One way to address water pollution issues is by utilizing high voltage. High-voltage direct current is applied to two electrodes spaced apart. By passing air through water contaminated with E. Coli bacteria between these two electrodes excited by a high-voltage source, water can be sterilized. High-voltage equipment is generated using a flyback transformer, controlled with PWM and frequency drivers, while a corona discharge plasma reactor is constructed with the geometry of two electrodes in the reactor tube. The test results indicate that the high-voltage equipment produces a variable voltage ranging from 0 volts to 50 kV, with a PWM driver and a frequency of 152.4 kHz. The content of E. coli bacteria in the water, before being treated with ozone, was initially 37 colonies. It has successfully decreased to 19 colonies at an ozone concentration of 0.16 ppm, further decreased to 2 colonies at an ozone concentration of 0.20 ppm, and reached 0 colonies at an ozone concentration of 0.29 ppm, meeting the requirements of PERMENKES RI No:907 /Menkes/SK/VII/2002 regarding good water quality, which specifies E. Coli bacteria content as 0 per 100 mlen_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectHigh voltageen_US
dc.subjectflyback transformeren_US
dc.subjectozoneen_US
dc.subjectescherichia colien_US
dc.subjectSDGsen_US
dc.titleRancang Bangun Generator Ozon dengan Tegangan Tinggi Arus Searah untuk Sterilisasi Air dari Bakteri Escherichia Colien_US
dc.typeThesisen_US
dc.identifier.nimNIM190402085
dc.identifier.nidnNIDN0001075904
dc.identifier.kodeprodiKODEPRODI20101#Teknik Elektro
dc.description.pages70 Halamanen_US
dc.description.typeSkripsi Sarjanaen_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record