    Rancang Bangun Alat Pengukur Kadar Gula Darah melalui Urin Berbasis Iot dengan menggunakan Arduino

    Thumbnail
    View/Open
    Cover.pdf (597.1Kb)
    Fulltext (6.938Mb)
    Date
    2023
    Author
    Tampubolon, Octovery Tri Putra
    Advisor(s)
    Mubarakah, Naemah
    Metadata
    Show full item record
    Abstract
    Diabetes is a disease caused by high blood sugar levels. Diabetes can also be considered as a disease caused by abnormal chemical reactions about the utilization of carbohydrates, fats and proteins of food due to underconsumption or lack of insulin. Sugar levels should be constantly monitored in patients so that the disease can be controlled by them. There are two methods to control blood glucose levels, namely Medical Laboratory Test (MLT) and Blood Glucose Meter (BGM). In this study, researchers have developed an IoT-based blood glucose meter using an Esp32 microcontroller. Measurements are made by observing the pH of the urine and also the color of the urine. The measurements use a TCS3200 color sensor and also a pH-4502C sensor. The circuit is designed using online EDA (Electronic Design Automation) software. From the results of the study can be seen that in color testing, the average error is 5.02%. This can be minimized by increasing the number of urine samples used in determining the conversion equation of the frequency combination into sugar levels because the regression equation is an equation determining predictions so that the more urine samples, the smaller the percentage error of the color sensor. In pH testing, it can be seen that all pH test results both using the assembled device do not exceed the threshold of diabetics, namely 4.5-5.5. The test also obtained the average result of urine pH testing error with an average error of 4.125%.
    URI
    https://repositori.usu.ac.id/handle/123456789/91652
    Collections
    • Undergraduate Theses [1465]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV