    Modifikasi Struktur Jetty Dermaga C Pt Pelindo 1 Dumai dari Memakai Pelat Beton Pracetak Konvensional Menjadi Pelat Beton Pracetak Hollow Core Slab

    Thumbnail
    View/Open
    Cover_187016027 (913.5Kb)
    List of Tables_187016027 (141.9Kb)
    List of Figures_187016027 (149.0Kb)
    Full Text_187016027 (6.020Mb)
    Date
    2023
    Author
    Soemakarya, Ahmad Amanu Surya
    Advisor(s)
    Tarigan, Johannes
    Metadata
    Show full item record
    Abstract
    he wharf is where the ships are moored in the harbour. In addition, the pier is also the place where loading and unloading of goods takes place and passengers boarding and falling from and to the ship. The dock is also the location for activities for refueling ships, supplying ships with drinking water, clean water, and arranging channels for dirty water/waste which will be further processed at the port. So that optimum planning is needed so that the performance of the building can meet safety and comfort standards This thesis examines conventional floor slabs and precast hollow core slabs at spans of 5.2 meters and 10.4 meters. Dead load is calculated based on specific gravity, live load and traffic load calculated using "Loading for Bridges" (SNI 1725-2016), crane load using Liebherr Brand Ship to Shore Gantry Cranes specifications with a capacity of 50 tons, ship berthing load and mooring load ships are calculated based on Technical standards and comments for port and harbor facilities in Japan, OCDI, 2020, while earthquake loads are calculated using "Bridge planning against earthquake loads" (SNI 2833:2016). Steel piles are calculated using "specifications for structural steel buildings" (SNI 1729:2015) and reinforced concrete structures are calculated using "Structural concrete requirements for buildings and explanations" (SNI 2847 2019). Structural analysis for structures is carried out using the help of SAP2000 software. The results showed an increase in the ratio of iron by 38.57% and a decrease in the shear capacity of the punch by 56.57% at a span of 5.2 meters. Meanwhile, for a span of 10.4 meters, an increase in iron ratio of 38.57% was obtained and a decrease in the shear capacity of the puncher was 56.57%. these results were obtained by modifying conventional precast floor slabs with hollow core slab precast floor plates
    URI
    https://repositori.usu.ac.id/handle/123456789/92135
    Collections
    • Master Theses [246]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV