• Login
    View Item 
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Mechanical Engineering
    • Undergraduate Theses
    • View Item
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Mechanical Engineering
    • Undergraduate Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Eksperimental Water Heater Tipe Helical dengan Memanfaatkan Panas Buang Kondensor Ac Split 3/4 PK Dengan Kapasitas 150 L

    Experimental Helical Type Water Heater Utilizing Waste Heat from a 3/4 PK Split Ac Condenser with a Capacity of 150 L

    Thumbnail
    View/Open
    Cover (1.275Mb)
    Fulltext (5.505Mb)
    Date
    2024
    Author
    Siregar, Triwan Indra
    Advisor(s)
    Sitorus, Tulus Burhanuddin
    Metadata
    Show full item record
    Abstract
    Basically, AC is used as an air conditioner, especially in hot areas to get thermal comfort. The heat energy that comes out of the condenser can be used to heat the air. This application of conservation energy is called Air Conditioner Water Heater (ACWH). ACWH utilizes hot freon which will flow to the Heat Exchanger which functions to heat the air in the holding tank. Through this, the author would like to convey that the use of ACWH can reduce costs and also save on electrical energy usage, thereby reducing global warming due to AC waste heat. The aim of this research is to analyze the maximum temperature produced by the discharge of the AC condenser to heat the air in the tube and analyze the performance of a water heater using a helical pipe. The results obtained from this research obtained the characteristics of this machine, namely the highest air temperature obtained was 45.2 C in testing with an air capacity of 75 L, the highest compressor power value obtained was 561.0 W, and the lowest was 542.3 W, and the COP was obtained during testing was an average of 3.0 -3.9, while the Standard AC had a COP with an average of 3,338, so this shows that the ACWH system does not have a big effect on the performance of the split AC
    URI
    https://repositori.usu.ac.id/handle/123456789/96674
    Collections
    • Undergraduate Theses [901]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV