• Login
    View Item 
    •   USU-IR Home
    • Faculty of Mathematics and Natural Sciences
    • Department of Physics
    • Undergraduate Theses
    • View Item
    •   USU-IR Home
    • Faculty of Mathematics and Natural Sciences
    • Department of Physics
    • Undergraduate Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Alat Kontrol pH Air Otomatis Pada Budidaya Ikan Air Tawar menggunakan Automatic Sensor Lifter Terintegrasi Internet Of Things (IoT)

    Automatic Water pH Control Tool in Freshwater Fish Farming using Automatic Sensor Lifter Integrated Internet of Things (Iot)

    Thumbnail
    View/Open
    Cover (635.9Kb)
    Fulltext (3.926Mb)
    Date
    2024
    Author
    Sinaga, Ulfa Maisari Sinaga
    Advisor(s)
    Nasution, Tulus Ikhsan
    Metadata
    Show full item record
    Abstract
    The accuracy of water pH measurement results during control and monitoring can determine the optimal water condition of fish ponds for fish growth and health in freshwater fish farming. By automatically controlling the pH of the water using an automatic sensor lifter, it can produce more accurate and practical measurements. In this study, a control device was created that can automatically control and monitor the pH of water using an automatic sensor lifter to lift and dip the pH sensor when taking measurements to minimize the inaccuracy of the pH sensor readings and keep the sensor in an optimal state. If the pH of the water is detected to be below 6.5 and above 8.5 the aerator pump will be activated as an aeration process to stabilize the pH value in a neutral state, and the measurement results will be displayed on the lcd, as well as the Blynk android application with data stored in the memory card. From the results of tests conducted on six conditions (two mornings, two afternoons, afternoons, and nights), it was obtained that the control device had a high accuracy level of 99.99% which was able to minimize the inaccuracy of sensor readings with the resulting calibration equation y = 43.521-12.955x. Testing in the morning, the accuracy level of the pH sensor at 06:00 WIB was 99.99% with a measured pH value of 6.9-7.3 and at 09:00 WIB the accuracy level was 99.99% with a measured pH value of 6.9-7.2. During the day at 12:00 WIB the accuracy level is 99.99% with a pH value of 7.0-7.3 and at 15:00 WIB the accuracy level is 99.99% with a pH value of 6.9-7.2. In the afternoon at 18:00 WIB the accuracy level is 99.99% with a pH value of 6.8-7.5 and at night at 21:00 WIB the accuracy level is 99.99% with a pH value of 6.4-7.3
    URI
    https://repositori.usu.ac.id/handle/123456789/97077
    Collections
    • Undergraduate Theses [1307]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV