• Login
    View Item 
    •   USU-IR Home
    • Faculty of Mathematics and Natural Sciences
    • Department of Chemistry
    • Undergraduate Theses
    • View Item
    •   USU-IR Home
    • Faculty of Mathematics and Natural Sciences
    • Department of Chemistry
    • Undergraduate Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Sensitivitas Elektroda Tembaga Termodifikasi Kitosan/Serium Oksida (CeO2) dalam Mendeteksi Konsentrasi Antibiotik Tetrasiklin dengan Siklik Voltammetri

    Sensitivity of Chitosan/Cerium Oxide (CeO2) Modified Copper Electrode in Detecting Concentrations of Tetracycline Antibiotics with Cyclic Voltammetry

    Thumbnail
    View/Open
    Cover (590.0Kb)
    Fulltext (1.952Mb)
    Date
    2024
    Author
    Siadari, Eviartha Ulina
    Advisor(s)
    Nainggolan, Irwana
    Metadata
    Show full item record
    Abstract
    Chitosan/Cerium Oxide (CeO2) modified copper electrode with a simple and sensitive has been successfully carried out using a cyclic voltammetric method to detect tetracycline antibiotic. The effect of the addition of cerium oxide on the chitosan has been shown to improve the sensing properties of the chitosan electrodes. Chitosan/CeO2 was fabricated using the electrodeposition method at a volume ratio of 1:1 in the form of a 1.5% chitosan solution and various CeO2 concentrations of 0.005, 0.0075, 0.001, 0.0125 and 0.015g. The sensing properties of the chitosan/CeO2 electrode were tested against tetracycline antibiotics with concentrations of 0.1, 0.5, 1, 1.5 and 2 ppm. The characteristics of the chitosan/CeO2 electrode were analyzed using the Scanning Electron Microscopy (SEM) and Fourier Transform Infra-Red (FT-IR) methods. The measurement parameters in this study are low E(V) = -1, high E(V) = +1, scan rate (mV/second) = 75, these parameters are used until the end of the test for analyzing tetracycline antibiotics using the cyclic voltammetry method. The results of the test produce the maximum output voltage of 0.0075g chitosan/CeO2 at a potential of 0.00328 V, a high performance chitosan/CeO2 based electrode used to detect variations in the concentration of tetracycline antibiotics. A tetracycline antibiotic concentration of 0.0075g produces the highest peak oxidation current and potential namely 7.05392 A and 0.992 V. The detection limit (LOD) and quantity limit (LOQ) for detecting tetracycline antibiotics are 0,5533 μM dan 1,8447 μM. The results of this research show that the modified chitosan/CeO2 electrode is able to detect tetracycline antibiotics with the lowest levels and good sensitivity so that it can be applied as a basic sensor material for detecting tetracycline antibiotics
    URI
    https://repositori.usu.ac.id/handle/123456789/97135
    Collections
    • Undergraduate Theses [1308]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV