• Login
    View Item 
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Civil Engineering
    • Undergraduate Theses
    • View Item
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Civil Engineering
    • Undergraduate Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Karakteristik Beton Segar Self Compacting Concrete dengan Substitusi Ground Granulated Blast Furnace Slag (GGBFS) Menurut Standart Efnarc

    Fresh Concrete Characteristics of Self Compacting Concrete with Ground Granulated Blast Furnace Slag (GGBFS) Susbstitute According to Efnarc Standards

    Thumbnail
    View/Open
    Cover (702.5Kb)
    Fulltext (5.281Mb)
    Date
    2024
    Author
    Siregar, Leny Serenita
    Advisor(s)
    Karolina, Rahmi
    Metadata
    Show full item record
    Abstract
    Self-Compacting Concrete (SCC) is a concrete that can flow and spread under its weight without segregation, fill the entire formwork, and through the reinforcement without mechanical consolidation. One effective way to reduce the environmental impact of cement production is to partially substitute the mineral mixture in concrete. Adding Ground Granulated Blast Furnace Slag (GGBFS) is expected to be a good substitute. The method used in this study is an experimental method by replacing the use of cement with Ground Granulated Blast Furnace Slag (GGBFS) material with variations of 0%, 10%, 20%, 30%, 40%, and 50%. SCC concrete will be tested when the concrete age reaches 7 days, 14 days, and 28 days for concrete compressive strength testing. From the results of fresh concrete testing, it can be concluded that the more GGBFS is added, the fresh concrete value on Slump Flow decreases, Slump Flow T50cm increases, v-funnel increases, and l-shape box decreases. The addition of Ground Granulated Blast Furnace Slag (GGBFS) in this study that meets the requirements of the concrete mixture is the variation of GGBFS 0%, 10%, and 20%. In comparison, the variations of 30%, 40%, and 50% cannot be classified as Self Compacting Concrete because they do not meet all the requirements. .The highest average compressive strength values at the age of 7 days, 14 days, and 28 days are 32.75 MPa, 39.52 MPa, and 50.97 MPa. The optimum compressive strength test of SCC concrete at a variation of 50% at a curing time of 28 days is 50.97 MPa
    URI
    https://repositori.usu.ac.id/handle/123456789/97462
    Collections
    • Undergraduate Theses [1512]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV