    Studi Sebaran Cemaran Air Limbah Domestik dari Tangki Septik pada Jenis Tanah Lanau

    Study of the Distribution of Domestic Wastewater from Septic Tanks in Silt Type Soil

    Thumbnail
    View/Open
    Cover (466.2Kb)
    Fulltext (3.918Mb)
    Date
    2024
    Author
    Gulo, Emmanuel
    Advisor(s)
    Herlina, Netti
    Faisal, Muhammad
    Metadata
    Show full item record
    Abstract
    The increasing of human population nowadays continues to drive the incessant growth of residential development. Continuous development will affect people's lives, especially the domestic wastewater management. People generally use septic tanks in domestic wastewater management, but this often do not comply with the provisions regulated in the SNI, which potentially polluting shallow groundwater. Because of these issues, the author conducted a laboratory simulation of septic tank wastewater seepage on a small scale. This research was carried out in a 100 cm x 100 cm x 40 cm glass box.The aim of this study was to determine the distribution distance, flow rate, and travel time of septic tank wastewater in a horizontal and vertical direction within the glass box. The distribution sumulation was performed using laboratory tests with 1:10 ratio according to the existing conditions and also the soil physical properties were tested. Contaminant parameters including the concentration of Escherichia coli and Ammonia (NH3N) were analyzed based on distance and time. The number of samples tested in this study was 20 point arranged diagonally.The results of soil physical property tests included specific gravity value of soil 2,643, plastic limit 33,51%, liquid limit 39,983%, plastic index 6,473%, sieve analysis 10,28%, moisture content 27% and permeability 4,582 x 10-5 cm/s. The results of Escherichia coli concentration tests at showed that the concentration was 15,1 x 107 (CFU/100 ml) at the closets distance from the source of spread and 3,6 x 107 (CFU/100 ml) at the farthest distance with the removal effieciency of 75.6%. The Ammonia (NH3N) concentration at the closest distance from the source of spread was 4,4 (mg/L) and at the farthest distance was 2,5 (mg/L) with the removal effieciency of 65.9%. The simulation results of the vertical spread of of septic tank wastewater in glass box at a distance 20 cm required a travel time of 269 minutes (4 hours and 29 minutes) with infiltration rate of 4,46 cm/hour and horizontal spread of in the glass box at a distance 80 cm required a travel time of 565 minutes (9 hours 2 5 minutes) with a septic tank wastewater spread speed/flow rate 7,2 x 10-3 Liter/minute
    URI
    https://repositori.usu.ac.id/handle/123456789/97472
    Collections
    • Undergraduate Theses [381]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV