• Login
    View Item 
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Civil Engineering
    • Undergraduate Theses
    • View Item
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Civil Engineering
    • Undergraduate Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Analisis Karakteristik Campuran Laston AC-WC Akibat Rendaman Air Laut Pasang (ROB) Kecamatan Medan Belawan Berdasarkan Uji Marshall dan Durabilitas

    Characteristic Analysis of Asphalt Concrete Wearing Course (AC-WC) Mixture Due to Rob Flood in Medan Belawan Sub-District Based on Marshall Test and Durability

    Thumbnail
    View/Open
    Cover (535.0Kb)
    Fulltext (2.952Mb)
    Date
    2023
    Author
    Purba, Rizal Perdian
    Advisor(s)
    Sembiring, Irwan Suranta
    Metadata
    Show full item record
    Abstract
    Tides are a natural phenomenon that often occurs in coastal areas of Indonesia, from low water levels to high water levels. Flooding occurs when sea water overflows onto land, a phenomenon known as storm flooding. In coastal areas affected by tidal surges, some roads are often damaged. Therefore, research is needed to study the impact of tidal damage on pavement. The objective of this study was to investigate the effect and durability of asphalt-concrete mixtures on the properties of AC-WC asphalt using Marshall and immersion durability tests. Two standard methods were used in this study: immersion in tidal sea water (Rob) and laboratory water. In the water immersion method, the samples (bjects to be tested) were immersed continuously in 60°C immersion water for 0.5 hours, 12 hours, 24 hours, and 48 hours. Some of the indicator indices used to determine the durability performance of AC-WC asphalt concrete are: Stability Retention Index (IRS), Primary Durability Index (IDP), and Secondary Durability Index (IDK). The results showed that the longer the immersion, the stability of the AC-WC mixture decreased, with a greater decrease in tidal water (14.953%) than laboratory water (8.847%). Flow values increased, with the highest value of 3.91 mm in laboratory water and 3.81 mm in tidal water. The decrease in Marshall Quotient (MQ) was also greater in tidal water compared to laboratory water. The longer the AC-WC mixture was submerged, its durability decreased based on the indicators of Residual Strength Index (IKS), First Durability Index (IDP), and Second Durability Index (IDK). The IKS in tidal water immersion was 92.216% and in laboratory water 95.547%, both of which are considered moderately durable. However, the IDP and IDK showed the mix to be more sensitive to strength loss in tidal water than in laboratory water.
    URI
    https://repositori.usu.ac.id/handle/123456789/98786
    Collections
    • Undergraduate Theses [1512]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV